Analog Read N Chans


Read the values of the specified analog input channels.

Inputs


Analog Ref Override
(Optional) Allows the analog reference voltage used to convert ADC ticks to volts to be overridden.

LINX Resource
Contains LINX connection resources.

AI Channel(s)
Specifies the analog channels to read from.

Error In
Describes error conditions that occur before this node runs. This input provides standard error in functionality.

Outputs


LINX Resource
Contains LINX connection resources.

Voltages
Returns the analog values in volts.

AI Ref
Returns the device's current analog input reference voltage.

Error Out
Contains error information. This output provides standard error out functionality.